  • Ammeter: Full Load Amperage vs. Service Factor Amperage

    A clamp-on ammeter allows you to measure current in your submersible installation system without breaking the circuit. Amperage, obtained from measuring current, can tell you whether or not a motor is overloaded or underloaded.

    • Duration 2m
    • Rating 4.0
  • Voltmeter: What is Voltage?

    One of the basic concepts we have to understand while troubleshooting a submersible water system is voltage, measured with a Voltmeter. Key takeaway from this video: voltage is pressure.

    • Duration 1m
    • Rating 4.0
  • Ammeter: What is Current?

    Current is measured by an ammeter in amperage or “amps.” Why this is valuable? Amperage tells you how hard the pump and motor are working.

    • Duration 1m
    • Rating 4.0
  • Ohmmeter: What is Resistance?

    In a water system we have something called friction loss. In an electrical system, we have the same thing known as resistance. This video takes a look at ohmmeters and how they can help you determine the condition of your...

    • Duration 2m
    • Rating 4.0
  • Megohmmeter: Measuring Insulation Resistance

    This video takes a look at megohmmeters, or meggers, and how you can measure insulation resistance in a submersible motor. Why is this important? So you can know the condition of your ENTIRE installation. 

    • Duration 2m
    • Rating 4.0
  • Capacitor Tester: What is a Capacitor?

    Capacitors, found in Franklin Electric single-phase control boxes, improve the performance of the motor. Rather than replacing the entire control box, consider checking the condition of the start  and run capacitors with a capacitor tester. 

    • Duration 1m
    • Rating 4.0
  • Ammeter: Measuring Amperage

    A clamp-on ammeter allows you to measure current in your submersible installation system without breaking the circuit. Amperage, obtained from measuring current, can tell you whether or not a motor is overloaded or underloaded.

    • Duration 2m
    • Rating 4.0
  • Ohmmeter: Measuring Winding Resistance

    This video takes a look at ohmmeters and how to measure winding resistance in a submersible motor. Why is this important? So you can know the condition of your motor. 

    • Duration 1m
    • Rating 4.0
  • Voltmeter: Supply Voltage vs. Nameplate Voltage

    It's important to distinguish and understand the difference between supply voltage and nameplate voltage when troubleshooting a submersible water system. This video will explain how.

    • Duration 1m
    • Rating 4.0
  • Voltmeter: Measuring Voltage

    When troubleshooting a submersible water system, a voltmeter is one of the key tools you will need. Here's a quick video guide to troubleshooting voltage with a voltmeter.

    • Duration 2m
    • Rating 4.0
  • Capacitor Tester: Troubleshooting

    For larger, single-phase Franklin Electric control boxes, troubleshoot the start and run capacitors using a capacitor tester. 

    • Duration 1m
    • Rating 4.0
  • Webinar

    You're familiar with FE Select, Franklin Electric's online sizing tool that quickly configures and quotes Franklin Electric products. Now, simplify your configuration tasks for Franklin Electric's FVT Series Vertical Lineshaft Turbines while having the flexibility to focus on the details that...

    • Event
    • Duration 45m
  • Options to Cover ALL Your Groundwater Training Needs 

    An industry aggregator focused on educating the contractor, NGWA University is a one-stop shop of online education. Announced at Groundwater Week 2020, this virtual tool is the perfect place to earn continuing education credits, train a new employee, or learn...

    • Webinar

      Looking to boost pressure in a commercial building, mining & construction, or municipal & wastewater application? We have a solution.  Engineered with high performance VR Series pumps and premium efficiency TEFC motors, the VR SpecPAK™ Pressure Boosting System can be...

      • Event
      • Duration 1h
    • Visit us at Groundwater Week 2020

      This year, National Groundwater Association's Groundwater Week is 100% virtual. We'll miss seeing you in person this year, but we'd still love to connect. Register now to earn CEU credits with our 4 workshops, learn more about our products viewing our 2 product demos, or get up...

      • How to Select Equipment Using FE Select

        This course introduces you to FE Select, an online sizing tool that quickly configures and quotes Franklin Electric products, providing you the ability to select, configure, view pricing, and generate quotes for your pump and control choices. During this course,...

        • Path
        • Duration 16m
        • Rating 5.0
        • Award
      • Webinar

        Product selection and configuration should be easy, for both new and experienced users. We'd like to introduce you to Pioneer Pump® products on FE Select, a digital pump software tool that makes product selection and configuration easy for distributors and...

        • Event
        • Duration 45m
      • Webinar

        Looking for a simplified, constant pressure solution? Meet Franklin Electric's SubDrive Utility™ Variable Frequency Drive. The SubDrive Utility provides constant pressure for 115 V and 230 V single-phase, two-wire systems and 230 V three-wire and three-phase systems up to 2...

        • Event
        • Duration 1h
        • Intermediate
      • Webinar

        Looking to sharpen your meter troubleshooting skills?  During this 1-hour webinar, Franklin Electric Southeast Region Field Service Engineer, Bob Lilland, will show you how to use the right tools in the right way to troubleshoot Franklin Electric products. This session...

        • Event
        • Duration 1h
        • Intermediate
      • Diagnosing Motors & Controls with Meters

        Looking to sharpen your meter troubleshooting skills?  During this 1-hour webinar, Franklin Electric Southeast Region Field Service Engineer, Bob Lilland, will show you how to use the right tools in the right way to troubleshoot Franklin Electric products. This session...

        • Duration 1h
      • Performance Beyond the Pump: IGP Series Retrofit Kits

        Do you need to replace a failed grinder or progressive cavity pump? Are you looking for a fast, simple, and reliable installation? We have a solution. Franklin Electric’s FPS IGP Series Retrofit Kits are designed as a direct replacement for...

        • Duration 30m
      • Webinar

        Downtime is expensive.  With a limited number of days to operate in the agriculture industry, any downtime while growing and harvesting crops or managing livestock can lead to a lower crop yield or decreased livestock value. Make every day of...

        • Event
        • Duration 30m
      • Improve Your Backup Plan with Pioneer Pump® Diesel-Driven Skid Packages

        Improve your municipal lift station backup plan with Pioneer Pump® Diesel-Driven Skid Packages. Less expensive with lower operating and maintenance costs, diesel-driven skid packages offer double protection in cases of both electrical failure and submersible pump failure. These packages also...

        • Duration 40m